INSTALLATION MANUAL
For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
Air-Conditioners For Building Application
INDOOR UNIT
PLFY-P·NAMU-E
Vedere la pagina 0
1 2 3 4 5 6 ... 15 16

Sommario

Pagina 1 - PLFY-P·NAMU-E

INSTALLATION MANUALFor safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.Air-Conditione

Pagina 2 - 1. Safety precautions

108.1. Checking the contents (Fig. 8-1)• This kit contains this manual and the following parts.Accessory name Q’ty Remark1 Grille 1 37-3/8 (950) × 37-

Pagina 3 - 2. Installation location

11ACDEFIGHACDBA Main unitB Detailed diagram of installed screw withwasher 2.C Corner drain pipe areaD Screw with washer 2 (for temporary use)E GrilleF

Pagina 4

12CABA Screw (4 × 8) 5B Corner panelC Safety wireFig. 8-108.7. Installing the intake grille (Fig. 8-10)Note:When reinstalling the corner panels (each

Pagina 8

Please be sure to put the contact address/telephone number onthis manual before handing it to the customer.This product is designed and intended for u

Pagina 9

21.2. Before installation or relocation Caution:• Be extremely careful when transporting the units. Two or more persons areneeded to handle the unit,

Pagina 10 - 7. Test run

32. Installation locationRefer to the outdoor unit installation manual.3. Installing the indoor unit3.1. Check the indoor unit accessories (Fig. 3-1)T

Pagina 11

43. Installing the indoor unitA UnitB GrilleC PillarD CeilingE RafterF BeamG Roof beamH Use inserts rated at 250-350 lbseach (procure locally)I Suspen

Pagina 12

54. Installing the refrigerant pipingA Flare cutting dimensionsCopper pipe O.D.Flare dimensions øA dimensions1/4" (ø6.35) 11/32-23/64 (8.7 - 9.1)

Pagina 13

64.3. Indoor unit (Fig. 4-3)Heat insulation for refrigerant pipes:1 Wrap the enclosed large-sized pipe cover around the gas pipe, making sure thatthe

Pagina 14

76.1. Power supply wiring (Fig. 6-1)Power cable size (diameter) : more than 1.6 mm (AWG14)Ground cable size (diameter) : 1.6 mm (AWG14)* Use copper su

Pagina 15

8BDCH,IAFEGBASW140SW110SW12012345678910ONOFFSW1SW5220V(208V)240V(230V)SWCCN82CN4332SWA123SWB421Address board6.3. Wiring connection (Fig. 6-5)1. Remove

Pagina 16 - BG79U666H01

96. Electrical work6.7. Remote controller1) Installing procedures(1) Select an installing position for the remote controller. (Fig. 6-7)The temperatur