4-way Ceiling Cassette
14
13
4-way Ceiling Cassette
SERIESSERIES
Advancements in PLA series improve
style and performance for ensured
indoor comfort
Wide Airflow
Wide-angle outlets distribute airflow to all
corners of the room, ensuring the room is
sufficiently cooled/heated. Horizontal airflow
and a fan speed reduced by 20% compared to
conventional models also contribute to
increased comfort for occupants.
Conventional model
PLA-RP
✽ ✽
BA
Less Cold Draught
The horizontal airflow function prevents
cold draughts from striking the body
directly,
thereby keeping the body from
becoming over-chilled.
Horizontal airflow
prevents draughty feeling
Independent Vane Direction
Setting
Use the wired remote controller to set
the airflow pattern of each vane
independently. Easily adjust airflow to
the interior layout and seasonal
conditions, and ensure an even
temperature distribution all the time.
Using wired remote controller,
set airflow direction for each vane
(manual setting also possible)
✽ Wired remote controller
(
PAR-21MAA/PAR-30MAA
)
has
Independent Vane Direction Setting.
This function is only available
when indoor unit connects
with PUHZ series.
Settings can be changed anytime
using a wired remote controller.
Vertical
flow
Horizontal
flow
Set by remote
controller
Fixed
Temperature gap with uneven
temperature distribution
Temperature gap is decreased,
and room is warmed uniformly
Swing mode
Vertical flow
Wave Airflow Mode for Heating
The airflow direction at
each outlet changes
intermittently, providing
a con
sistent temperature
through-
out the room.
Vertical
flow
Vertical
flow
Vertical
flow
Vertical
flow
Simultaneous horizontal and vertical operation ensure
a comfortable room from corner to corner.
● “Wave Airflow” operation image
● Wave control effect thermograph
Auto Fan Speed Mode
The fan speed is adjusted automatically, thereby maintaining a
comfortable room environment at all times. At the start of operation, a
high fan speed realises quick heating/cooling of the room. Once the
desired temperature is reached, the fan speed is reduced for stable
heating/cooling and greater comfort.
HiLo AutoMi1 Mi2
Fan speed setting by remote controller
(
four levels
)
✽Special setting is required for wireless remote controller.
Quiet Operation
An improved airflow path and powerful high-
capacity flow fan contribute to the realisation of
quieter operation.
Power flow fan
“Pure White” Colour
Stylish, pure white-coloured panels and wired remote controller
express a clean, streamlined image that is a suitable match for any
interior.
Other Features
•
Stylish indoor-unit vane covers (when unit is turned off)
• Maximum upward draining of 850mm
• Wireless remote controller available
• Duct flange for Fresh-air Intake
• Branch duct
Automatic Grille Lowering
Function
(
Option
)
Easy to use/Simple maintenance
An automatic grille lowering function capable
of stopping at eight different heights is
available to simplify filter maintenance.
Packaged elevating (up-down)
controller in the grille
(
PLP-6BAJ
)
can be used when outdoor unit is
both PUHZ series and SUZ series.
1.2m
1.6m
2.0m
2.4m
2.8m
3.2m
3.6m
4.0m
Automatic
elevation to
four metres
4-way cassettes can be equipped with the i-see Sensor,
a radiation-based sensor that monitors floor-level
temperatures throughout the room to
ensure room comfort.
i-see Sensor works to
ensure even temperature
distribution and save
energy (requires optional
corner panel)
i-see Sensor improves energy efficiency and enhances room comfort
The i-see Sensor is an innovative Mitsubishi Electric technology that uses a
radiation-based sensor to monitor temperature throughout the entire room.
When connected to the air conditioner control panel, i-see Sensor works to
maximise room comfort through 360° sensing that covers the whole floor space.
The i-see Sensor rotates 90° and takes 5-second
measurements to accurately determine floor-level
temperatures on all sides of the room.
■ i-see Sensor Operation
● The i-see Sensor calculates the temperature by measuring the infrared rays emanating
from the walls and floors, and measuring the floor-level temperature.
● The sensor rotates 360-degrees once every two minutes when there is significant
temperature disparity and once every five minutes when a stable, even temperature has
been reached.
90°
rotation
90°
rotation
90°
rotation
5sec
measurement
5sec
measurement
5sec
measurement
5sec
measurement
360°
Floor-level temperature
measured throughout the room.
2.7m
Set temperature: 20°C
with i-see Sensor + Auto Fan Speed
Without i-see Sensor
With i-see Sensor
Area which the
“i-see Sensor”
checks
Indoor temperature
detecting sensor
Indoor temperature
detecting sensor
Area which the
sensor checks
Set temperature: 23°C
without i-see Sensor
37°C
“I Feel” Temperature Control
The sensory temperature is calculated by measuring the air-intake temperature
and the floor temperature. This technology makes it possible to avoid
overcooling or overheating.
sensing
11.5m
2.7m
sensing
11.5m
25°C
13°C
37°C
25°C
13°C
Heating Heating
2.7m
Area which the
i-see Sensor
checks
Indoor temperature
detecting sensor
Indoor temperature
detecting sensor
Area which the
sensor checks
360°360°
sensing
11.5m
2.7m
sensing
11.5m
Only intake-air temperature at the
ceiling is measured, resulting in
uneven temperature distribution.
Both floor-level and intake-air tem-
peratures are measured, providing op-
eration that creates a comfortable
room environment from ceiling to floor.
Wired remote controller
(
PAR-21MAA/PAR-30MAA
)
has
automatic grille lowering function.
This function is only available
when indoor unit connects with
PUHZ series.
Elevating (up-down)
controller
optional
PLA-RP60/71
100/125/140BA
(
i-see Sensor: optional
)
Indoor unit
Specifications: 4-way ceiling-cassette (PLA)
PLA-RP60BA
PLA-RP60BA
SU Z-K A 60VA3
Cooling Heating
Outdoor unit
Function
Capacity (min.-max.)
Input
Rated EER/COP
Indoor unit
Power supply
Airflow
(
Lo-Mi2-Mid-Hi
)
Sound pressure level
Dimensions Width
Depth
Height
(
kW
)
(
kW
)
L/S
(
dB
)
(
kg
)
(mm)
(mm)
(mm)
Weight
✽ MEPS compliant at part load
CMM
PL A-RP71BA
PL A-RP71BA
12-14-16-18 14-16-18-21
200-233-267-300 233-267-300-350
28-29-31-32 28-30-32-34
SU Z-K A71VA3
Cooling Heating
6.1 (1.1- 6 .3 ) 6.9 (0.9-8.0) 7.1 ( 0.9 -8.1) 8.0 (0.9-10.2)
1.78 1.97 2.07 2.19
3.43 3.50 3.43 3.65
PL A-RP71BA
PL A-RP71BA
14-16-18-21
233-267-300-350
28-30-32-34
PUHZ-RP71VHA5
Cooling Heating
PL A-RP100BA
PL A-RP100BA
20-23-26-30
334-384-434-501
32-34-37-40
Unit: 25, Panel: 6
22-25-28-31
367- 417- 467-517
34-36-39-41
Unit: 840, Panel: 950
Unit: 298, Panel: 35
Unit: 840, Panel: 950
24-26-29-32
400-434-484-534
36-39-42-44
Unit: 27, Panel: 6
PU HZ- RP10 0V/ Y K A 2
Cooling Heating
PLA-R P125BA
PLA-R P125BA
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
Unit: 258, Panel: 35
Unit: 23, Panel: 6
PU HZ- RP125 V/ YK A2
Cooling Heating
PL A-RP140BA
PL A-RP140BA
PU HZ- RP14 0V/ YK A 2
Cooling Heating
13.0 ( 6.2-15.3 )
3.97
3.27
16.0 (5.7-18.0)
4.43
3.61
12.5 (5.5-14.0)
3.80
3.29
14.0 (5.0-16.0)
3.71
3.77
10.0 (4.9-11.4)
2.50
4.00
11.2 (4.5-14.0)
2.95
3.80
2.09
3.40
2.17
7.1 ( 3.3 -8.1) 8.0 ( 3.5-10. 2)
3.69
Rated AEER/ACOP
AEER/ACOP (part-load %)
✽
3.36 3.44 3.38 3.60
3.10 / 3.0 8
3.95/3.89
3.44/3.423.10 / 3.0 8
4.13/4.05
3.56/3.543.67/3.63 3.54/3.503.22 3.49