OC185A-1
CONTENTS
1. TECHNICAL CHANGE················································································OC185A- 1
2. FEATURES ··································································································OC185A- 2
3. PART NAME AND FUNCTIONS ·································································OC185A- 3
4. SPECIFICATIONS ·······················································································OC185A- 4
5. DATA············································································································OC185A- 5
6. OUTLINES AND DIMENSIONS ··································································OC185A-12
7. REFRIGERANT SYSTEM DIAGRAM·························································OC185A-14
8. WIRING DIAGRAM······················································································OC185A-15
9. OPERATION FLOW-CHART·······································································OC185A-16
10. MICROPROCESSOR CONTROL ·······························································OC185A-19
11. TROUBLESHOOTING·················································································OC185A-28
12. DISASSEMBLY PROCEDURE····································································OC185A-31
13. PARTS LIST·································································································OC185A-34
PK18FL, PK18FL1
PK24FL, PK24FL1
PK30FL, PK30FL1
PK36FL, PK36FL1
OC185A--1.qxp 1.12.19 10:23 AM Page 1
Vedere la pagina 0
1 2 3 4 5 6 ... 37 38

Sommario

Pagina 1 - PK36FL, PK36FL1

OC185A-1CONTENTS1. TECHNICAL CHANGE················································································OC185A- 12. FEATURES ··············

Pagina 2 - FEATURES

OC185A-104. OPERATING RANGE1) POWER SUPPLY2) OPERATION5. OUTLET AIR SPEED AND COVERAGE RANGE● The air coverage range is the value up to the position w

Pagina 3 - PART NAME AND FUNCTIONS3

OC185A-1190807060504030201063 125 250 500 1000 2000 4000 8000APPROXIMATETHRESHOLD OFHEARING FORCONTINUOUSNOISENC-60NC-50NC-40NC-30NC-20NC-70OCTAVE BAN

Pagina 4 - 4 SPECIFICATIONS

OC185A-126OUTLINES AND DIMENSIONS1. Indoor UnitPK18/24FLPK18/24FL19-1/41-25/329-1/41-25/329-1/4 9-1/41-25/321/213-3/87-3/41-21/322-9/32TopFrontRight s

Pagina 5 - OC185A-5

OC185A-13PK30/36FLPK30/36FL166-5/329-1/453-15/16 Air IntakeFrontKnock out holeRight side9-1/47-3/4Cfor right pipingBAABC4-1/32Liquid pipe 1/2FGas pip

Pagina 6 - OC185A-6

OC185A-1423/326-1/321/82-1/42-5/32TEMP POWER ON / OFFNOT AVAILABLEAMPMAMPM˚FCOOL DRYFANFANSWINGSET TEMPONOFFUnit : inch2. Remote controllerWIRELESS RE

Pagina 7 - OC185A-7

OC185A-15WIRING DIAGRAM8Indoor UnitPK18/24/30/36FLPK18/24/30/36FL1GRNL1GROUNDPOWER SUPPLY~(1 PHASE)AC115V 60Hz7TB2CNBLD1RuSW1W.RW.BREMOTECONTROLLER2TO

Pagina 8 - OC185A-8

OC185A-169 OPERATION FLOW-CHARTSTARTPower circuitbreakerCheck SWON twiceOperation SWON“OFF” timer“ON” timerSTOPSet timecompleteSet timecomplete1NONONO

Pagina 9 - OC185A-9

OC185A-17COOL operationInitialCOOLINGNONONONONOYESYESYESYESYESYESNOYESYESYESYESYESYESYESYESYESYESYESNONONONOYESNONONONONONONONONOw 8w 9Vane initialset

Pagina 10 - OC185A-10

OC185A-18w8—9 Refer to page OC185A-17.w12 When room temperature is 64°F or below, the compressor cannot operate.When room temperature rises over 64°F

Pagina 11 - OC185A-11

OC185A-19MICROPROCESSOR CONTROL101. OUTLINE OF MICROPROCESSOR CONTROL● OFF-ON switching.● COOL • DRY • FAN selector switching.● HIGH-LOW fan speed swi

Pagina 12 - OUTLINES AND DIMENSIONS

OC185A-21TECHNICAL CHANGE2FEATURES1. COMPACT DESIGNThe PK series models have been downsized and now require such minimal wall space that they can even

Pagina 13 - OC185A-13

OC185A-202. INDOOR UNIT CONTROL2-1COOL operation<COOL operation time chart>TEMP POWER ON / OFFNOT AVAILABLEAMPMAMPM˚FCOOL DRYFANFANSWINGSET TEMP

Pagina 14 - REFRIGERANT SYSTEM DIAGRAM

OC185A-215 Coil freeze protectionWhen the indoor coil temperature becomes - 5°F or below, coil freeze protection will proceed as follows.<Start con

Pagina 15 - WIRING DIAGRAM

OC185A-222-2 DRY operation<How to operate>1 Press POWER ON/OFF button.2 Press MODE button to set operation mode to DRY.3 Set desired temperature

Pagina 16 - 9 OPERATION FLOW-CHART

OC185A-23(2) Indoor fan controlThe indoor fan runs on LOW speed during compressor operation. The fan speed cannot be changed with the remote con-troll

Pagina 17 - OC185A-17

OC185A-24(1) Turn on the main power of unit.(2) Turn the adjusting switch on the back of the wireless remote controller to “SET” CHECK and TEST RUN

Pagina 18 - OC185A-18

OC185A-25Switches are located on the indoor unit PC board and inside the remote controller as shown.• Setting the SW1 (PC board inside indoor unit)Sub

Pagina 19 - OC185A-19

OC185A-262-8 Function of jumper wire and dip switch on indoor controller board1. Jumper wire1 JR1:Jumper wire for the auto vanes.Cut JR1 for the unit

Pagina 20 - OC185A-20

OC185A-272 SW2 (Unit selector switch)SW2-1) Switch for air conditioner with or without electric heater ON:Unit with electric heaterOFF:Unit without e

Pagina 21 - OC185A-21

OC185A-2811TROUBLESHOOTING(1) Turn on the main power of the unit.(2) Turn the adjusting switch on the back of the wireless remote con-troller to “SET”

Pagina 22 - OC185A-22

OC185A-29CheckcodeDiagnosis of malfunction Cause Check points4Abnormality of drain sensor 1) Bad contact of transmissionwire2) Damaged thermistor1) Ch

Pagina 23 - OC185A-23

OC185A-3PART NAME AND FUNCTIONS3TEMP POWER ON / OFFNOT AVAILABLEAMPMAMPM˚FCOOL DRYFANFANSWINGSET TEMPONOFFMODEFANVANE STOPSTARTCLOCKTIMER SETHR MIN. P

Pagina 24 - Press the reset button

OC185A-303. WRONG WIRING ON SITESymptom due to wrong wiring between indoor and outdoor units4. HOW TO CHECK THE PARTSWrong wiring Thermostat Phenomena

Pagina 25 - OC185A-25

OC185A-31DISASSEMBLY PROCEDURE12OPERATING PROCEDURE PHOTOS&ILLUSTRATIONMetal fixtureScrews1. Removing the lower side of the indoor unit from the i

Pagina 26 - OC185A-26

OC185A-32OPERATING PROCEDURE PHOTOS&ILLUSTRATION(8) Remove the screws of the indoor controller board case,and pull out the indoor controller board

Pagina 27 - OC185A-27

OC185A-33OPERATING PROCEDURE PHOTOS8. Removing the line flow fan and the fan motor(1) Remove the left and right side panels. (2) Remove the grilles. (

Pagina 28 - TROUBLESHOOTING

OC185A-3413 PARTS LISTELECTRICAL PARTSPK18FL, PK18FL1PK24FL, PK24FL1PK30FL, PK30FL1PK36FL, PK36FL1No.Parts No. Parts Name SpecificationsRemarks(Drawin

Pagina 29 - OC185A-29

OC185A-3567891011121314151617181920212223242526JOINT SHAFTCENTER COVERAUTO VANE WAUTO VANE WDRAIN HOSEVANE MOTORROOM TEMPERATURE THERMISTORPIPIE TEMPE

Pagina 30 - OC185A-30

OC185A-36STRUCTURAL PARTSPK18FLPK18FL1PK24FLPK24FL1Part number that is circled is not shown in the figure.12345678910SIDE PANEL (L) WUNDER PLATE WUNDE

Pagina 31 - DISASSEMBLY PROCEDURE

OC185A-371234567891011SIDE PANEL (L) WUNDER PLATE WUNDER PLATE WNOSE WNOSE WAIR FILTER WWIRELESS ADAPTER BOARDSIDE PANEL (R)INTAKE GRILLE WINTAKE GRIL

Pagina 32 - OC185A-32

3400 Lawrenceville Suwanee Road ● Suwanee, Georgia 30024 Toll Free: 800-433-4822 ● Toll Free Fax: 800-889-9904 www.mrslim.com Specifications ar

Pagina 33 - OC185A-33

OC185A-44 SPECIFICATIONSCapacityPower consumptionEERSEERINDOOR UNIT MODELExternal finishPower supplyMax. fuse size (time delay)Min ampacityFan motorAi

Pagina 34 - 13 PARTS LIST

OC185A-5DATA5Notes 1. B.F. : Bypass Factor, IWB : Intake air wet-bulb temperature TC : Total Capacity (x103 Btu/h), SHC : Sensib

Pagina 35 - OC185A-35

OC185A-6427167637167633036244.54.03.53.02.5023 323545 5565(67) 7585 95 105 115Total capacity (✕103 Btu/h)Total power consumption (kW)Outdoor intake ai

Pagina 36 - OC185A-36

OC185A-7Data is based on the condition of indoor humidity 50%.Air flow should be set at HI.A point on the curve shows the reference point.PK18FLPK18FL

Pagina 37 - OC185A-37

OC185A-8Data is based on the condition of indoor humidity 50%.Air flow should be set at HI.A point on the curve shows the reference point.Outdoor ambi

Pagina 38 - ● Suwanee, Georgia 30024

OC185A-93. STANDARD OPERATION DATA750 750750750 760 760CapacitySHFInputINDOOR UNIT MODELPower supply (V, phase, Hz)InputFan currentOUTDOOR UNIT MODELP