Mitsubishi Electric PUZ-HA36NHA4 Manuale Utente

Navigare online o scaricare Manuale Utente per Alimentatori e invertitori Mitsubishi Electric PUZ-HA36NHA4. P-SERIES Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 4
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
P-SERIES
Specications are subject to change without notice.
© 2014 Mitsubishi Electric US, Inc.
Job Name:
System Reference: Date:
Indoor Unit: PCA-A36KA4
SUBMITTAL DATA: PCA-A36KA4 & PUZ-HA36NHA4
36,000 BTU/H CEILING-SUSPENDED HYPER HEAT-PUMP SYSTEM
ACCESSORIES
Indoor Unit
Condensate Pump (PAC-SH84DM-E)
High-efciency Filter (MERV 8) (PAC-SH89KF-E)
Outdoor Unit
M-NET Adapter (PAC-SF81MA-E)
Wind Bafe (One Piece)* (WB-PA2)
Air Outlet Guide (One Piece)* (PAC-SG59SG)
*PUY(Z) requires two outlet guides or wind bafes for installation.
GENERAL FEATURES
High heating capacity at low outside temperatures
Exhibits 100% of rated heating capacity at 5º F; 90% of rated heating capacity at -4º F
Built-in drain lift mechanism for condensate removal; lifts up to 33-7/16 inches
Wide air ow pattern for better air distribution; independently adjustable vanes
Auto wave airow in heating mode—unit independently cycles through horizontal and vertical positions for a more even heat distribution
Self-check function—integrated diagnostics
Limited warranty: ve years parts and seven years compressors
Controller Options
Wireless Wall-mounted Remote Controller Kit (MHK1)**
Portable Central Controller (MCCH1)**
Outdoor Air Sensor (MOS1)**
Wired Wall-mounted Controller (PAR-31MAA)**
Simple MA Remote Controller (PAC-YT53CRAU)**
**See Submittal for information on each option.
M-NET Adapter (PAC-SF81MA)
CN51 Connector for Multiple Remote Controller Adapters/Duct Fan Controller (PAC-725AD)
CN24 Relay Kit (CN24RELAY-KIT-CM3)
CN32 Connector for Remote On/Off (PAC-715AD)
Remote Temperature Sensor (PAC-SE41TS)
Remote Operation Adapter - Display and On/Off (PAC-SF40RM)
Wireless Remote Control with Receiver Kit (PAR-SL93B-E)
i-see Sensor Corner Panel (PAC-SA1ME)
Wireless Remote Control with Receiver and i-see Sensor Kit (PAR-SA92MW-E)
i-see Sensor (PAC-SH91MK-E)
Lockdown Bracket for Hand-held Controller (RCMKP1CB)
Control/Service Tool (PAC-SK52ST)
SEACOAST PROTECTION
External Outer Panel: Phosphate coating + Acrylic-Enamel coating
Fan Motor Support: Epoxy resin coating (at edge face)
Separator Assembly ; Valve Bed: Epoxy resin coating (at edge face)
Screws (used outer side): Zinc nickel coating 5μm + Polyvinylidene chloride coating
“Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants..
Outdoor Unit: PUZ-HA36NHA4
Vedere la pagina 0
1 2 3 4

Sommario

Pagina 1 - P-SERIES

P-SERIESSpecications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc.Job Name:System Reference: Date:Indoor Unit: PCA-A36KA

Pagina 2 - H 9-1/16 / 230

Specications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc.SPECIFICATIONS: PCA-A36KA4 & PUZ-HA36NHA4ELECTRICAL REQUIR

Pagina 3 - DIMENSIONS: PCA-A36KA4

Specications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc.DIMENSIONS: PCA-A36KA4If the piping is installed in the backof

Pagina 4 - DIMENSIONS: PUZ-HA36NHA4

Specications are subject to change without notice. © 2014 Mitsubishi Electric US, Inc.1340 Satellite Boulevard Suwanee, GA 30024Toll Free: 800-433-4