Job Name: Location: Date:
Purchaser: Engineer:
Submitted to: For Reference Approval Construction
Unit Designation: Schedule No.:
Cooling*
Rated Capacity...............................30,000 Btu/h
Minimum Capacity ............................12,000 Btu/h
SEER ..................................... 15.5 Btu/h/W
EER ....................................... 7.7 Btu/h/W
Total Input......................................3,850 W
* Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB / 67ºF (19ºC) WB.
Outdoor: 95ºF (35ºC) DB / 75ºF (24ºC) WB.
Electrical Requirements
Power Supply ....................208 / 230V, 1-Phase, 60 Hz
Recommended Fuse/Breaker Size.......................30 A
Voltage
Indoor - Outdoor S1-S2 ......................AC 208 / 230V
Indoor - Outdoor S2-S3 ............................DC24V
OPERATING CONDITIONS
Indoor Intake Air Temp. Outdoor Intake Air Temp.
Cooling
Maximum 95ºF (35ºC) DB, 71ºF (22ºC) WB 115ºF (46ºC) DB
Minimum 67ºF (19ºC) DB, 57ºF (14ºC) WB 0ºF** (-18ºC) DB
** With optional wind bafe accessory installed. If not installed, the minimum
temperature will be 23ºF (-5ºC) DB.
Indoor Unit: PEAD-A30AA4
Outdoor Unit: PUY-A30NHA4
SUBMITTAL DATA: PEAD-A30AA4 & PUY-A30NHA4 . . . . . . . . . . . . . .30,000 BTU/H HORIZONTAL-DUCTED AIR CONDITIONING SYSTEM
GENERAL FEATURES
• Horizontal-ducted indoor unit features medium static pressure
capability
• Thin body: 9-7/8" high
• Built-in drain mechanism for condensate removal; lifts to 27-9/16"
• Setback down to 50°F when used with MRCH1 Central Controller
• Air lter is included with indoor unit
• Quiet operation—both indoor and outdoor units
• Automatic fan speed control
• Auto restart following a power outage
• Self-check function—integrated diagnostics
• Knockout for ventilation air
• Limited warranty: ve years on parts and defects and seven years
on compressors
Indoor Unit
MCA ............................................ 2.73 A
Fan Type x Quantity ......................... Sirocco fan x 2
Fan Motor Type ............. Direct-driven DC Brushless Motor
Fan Motor ....................................2.18 F.L.A.
Fan Motor Output ..................................121 W
Airow (Lo - Mid - Hi) ................ 618 - 742 - 883 Dry CFM
565 - 671 - 812 Wet CFM
Air Filter .........................Polypropylene Honeycomb
External Static Pressure...... 0.14 - 0.20 - 0.28 - 0.40 - 0.60"WG
Sound Pressure Level (Lo - Mid - Hi) ..........30 - 34 - 39 dB(A)
SHF ..............................................0.68
Moisture Removal.................................8.6 pt./h
DIMENSIONS UNIT INCHES / MM
W 43-5/16 / 1,100
D 28-7/8 / 732
H 9-7/8 / 250
Weight ....................................73 lbs. / 33 kg
External Finish .......................Galvanized-steel Sheet
Field Drainpipe Size O.D...................... 1-1/4" / 32 mm
Outdoor Unit
Compressor ...................DC Inverter-driven Twin Rotary
MCA ..............................................25 A
MOCP.............................................40 A
Fan Motor .....................................0.75 F.L.A.
Sound Pressure Level (Cooling).....................48 dB(A)
DIMENSIONS INCHES / MM
W 37-3/8 / 950
D 13 + 1-3/16 / 330 + 30
H 37-1/8 / 943
Weight ...................................163 lbs. / 74 kg
External Finish ......................Munsell No. 3Y 7.8 / 1.1
Refrigerant Type ...................................R410A
Refrigerant Pipe Size O.D.
Gas Side ................................5/8" / 15.88 mm
Liquid Side................................3/8" / 9.52 mm
Max. Refrigerant Pipe Length..................... 165' / 50 m
Max. Refrigerant Pipe Height Difference ............ 100' / 30 m
Connection Method ................................Flared
OPTIONAL ACCESSORIES
Indoor Unit
□ Filter Box with MERV 13 Filters (FBM2-3)
Outdoor Unit
□ Drain Pan (PAC-SG64DP)
□ Drain Socket (PAC-SG61DS)
□ Three-pole Disconnect Switch (TAZ-MS303)
□ Wind Bafe (WB-PA2)
□ Air Outlet Guide (PAC-SG59SG)
□ Mounting Base (DSD-400N)
□ Mounting Pad (ULTRILITE2)
□ Wall-mounting Brackets (CWMB1)
Controller Options
□ Wireless Remote Controller Kit (MHK1) with Wall-mounted Central
Controller (MRCH1), Wireless Receiver (MIFH1), and cable*
□ Wall-mounted Central Controller (MRCH1)*
□ Wireless Receiver (MIFH1)*
□ Portable Central Controller (MCCH1; for use with Wireless Remote
Controller Kit MHK1)*
□ Outdoor Air Sensor (MOS1; for use with Central Controller (MRCH1),
Wireless Remote Controller Kit (MHK1) and Portable Central Controller
(MCCH1)*
*See Submittal for information on each option.
□ Wall-mounted Wired Remote Controller (PAR-21MAA)
□ M-NET Adapter (PAC-SF81MA)
□ CN51 Connector for Multiple Remote Controller Adapters/Duct Fan
Controller (PAC-725AD)
□ CN32 Connector for Remote On/Off (PAC-715AD)
□ Remote Temperature Sensor (PAC-SE41TS)
□ Remote Operation Adapter - Display and On/Off (PAC-SF40RM)
□ Handheld Wireless Remote Controller (PAR-FL32MA; req.
PAR-SA9CA)
□ Wireless Signal Receiver Module (PAR-SA9CA)
□ Lockdown Bracket for Handheld Controller (RCMKP1CB)
□ Control/Service Tool (PAC-SK52ST)