Mitsubishi Electric FR-F720-0.75K to 110K Manuale delle Istruzioni

Navigare online o scaricare Manuale delle Istruzioni per Alimentatori e invertitori Mitsubishi Electric FR-F720-0.75K to 110K. Mitsubishi Electric FR-F720-0.75K to 110K Instruction manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 62
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
FR-A 500/FR-F 500/
FR-E 500/FR-S 500/
FR-F 700 EC
Frequency Inverter
Instruction Manual
FR-SW1-SETUP-WE
Version 3.1
INDUSTRIAL AUTOMATION
MIT
SU
BI
S
HI ELE
C
TRI
C
MIT
SU
BI
S
HI ELE
C
TRI
C
Art. no.: 132733
01 11 2004
IB(NA)-0600081
Version C
Vedere la pagina 0
1 2 3 4 5 6 ... 61 62

Sommario

Pagina 1 - FR-F 700 EC

FR-A 500/FR-F 500/FR-E 500/FR-S 500/FR-F 700 ECFrequency InverterInstruction ManualFR-SW1-SETUP-WEVersion 3.1INDUSTRIAL AUTOMATIONMITSUBISHI ELECTRICM

Pagina 2

4Preparations for Startup[Connection example between converter and inverter (PU connection port)]1.2.2 Installing the Setup SoftwareTo use the VFD Set

Pagina 3 - For Maximum Safety

5Preparations for StartupOVERVIEW1(3) Running the installation program1) The [Run] dialog box appears.2) Type "D:\SETUP" (use half-size lett

Pagina 5 - 4 APPENDICES 47

712342 FUNCTIONS2.1 Starting the VFD Setup Software...82.2 Settings...

Pagina 6

8Starting the VFD Setup Software2.1 Starting the VFD Setup SoftwareStart the VFD Setup Software with "INVSUPE.EXE".<Primary screen><

Pagina 7

9SettingsFUNCTIONS22.2 SettingsWhen you press the [OK] button on the initial screen, the following screen appears:(1) Menu listThis software has the f

Pagina 8 - Instruction manual 1 book

10Settings(2) Description of various buttons and indications1) Node The station number selected is displayed.2) [EXT] (Alt+X), [PU] (Alt+U) and [LNK]

Pagina 9 - 1.2 Preparations for Startup

11SettingsFUNCTIONS22.2.1 System SettingsThis screen appears when you start this software and press the [OK] button on the initial screen.On this scre

Pagina 10 - Preparations for Startup

12Settings2.2.2 Communication SettingsThe VFD Setup Software uses the serial port of the personal computer to control the inverters through serialcomm

Pagina 11 - OVERVIEW

13SettingsFUNCTIONS2(3) Inverter communication settingsThe values set for communication depend on the inverter and connection method.(4) Interrogate t

Pagina 13 - FUNCTIONS

14Parameter2.3 ParameterWhen system settings are complete, you can choose menu parameters.Choose the [Parameter] → [All List Format], [Functional List

Pagina 14 - <Initial screen>

15ParameterFUNCTONS27) Change List (Alt+G) ... Lists the parameters with the present set values which have been changedfrom the initi

Pagina 15 - 2.2 Settings

16ParameterCAUTIONIf an error occurred during "block read", "block check" or "block write", the parameter list appears o

Pagina 16 - Settings

17ParameterFUNCTONS22.3.2 Functional List FormatBy choosing the [Parameter] → [Functional List Format] command in the menu, the parameters are display

Pagina 17 - 2.2.1 System Settings

18Parameter2.3.3 Individual List FormatBy choosing the [Parameter] → [Individual List Format] command in the menu, you can select two different usergr

Pagina 18 - 2.2.2 Communication Settings

19ParameterFUNCTONS22.3.4 Basic SettingsChoosing the [Parameter] → [Basic Settings] command in the menu displays the following screen.By entering data

Pagina 19 - 2.2.3 Environmental Setting

20Monitor2.4 MonitorChoosing the [Monitor] - [Data Display], [Meter Display], [Oscilloscopes], [Alarm History] or [Trace Oscilloscopes]command in the

Pagina 20 - 2.3 Parameter

21MonitorFUNCTIONS22.4.2 Meter DisplayMeter Display shows four different signals (those of up to four stations) as meters in real time. Meter Displayh

Pagina 21 - FUNCTONS

22Monitor[Operating procedure][Timing] ... Choose the displayed data from among "Before", "During" and "Af

Pagina 22

23MonitorFUNCTIONS22.4.4 Alarm HistoryAlarm History displays the history of eight past alarms of all inverter stations connected.Choosing the [Monitor

Pagina 23 - 2.3.2 Functional List Format

INTRODUCTIONThank you for choosing the Mitsubishi Transistorized VFD Setup Software. This instruction manual gives handling information and precaution

Pagina 24 - 2.3.3 Individual List Format

24Monitor2.4.5 Trace Oscilloscopes (for FR-V500 (L) series only)The FR-V500 (L) series allows you to trace various data by setting Pr. 520 to Pr. 536

Pagina 25 - 2.3.4 Basic Settings

25MonitorFUNCTIONS2•Explanation of the buttons and indications1) Channel setting indicationShows a data name according of the setting of each channel.

Pagina 26 - 1) 2) 5) 6)

26Monitor15) Reference DataClicking [Reference Data] shows the data display reference value setting screen.Clicking [ ]/[ ] varies the reference value

Pagina 27 - Present Val

27MonitorFUNCTIONS2(2) Trace function setting screenBy changing the set values on the trace function setting screen and writing them to the parameters

Pagina 28 - [Operating procedure]

28Monitor(3) Parameter list(4) Parameter details1. Trace status (Pr. 52, Pr. 190 to Pr. 192, Pr. 195)The trace progress status, data output status and

Pagina 29 - 5) 4) 1)

29MonitorFUNCTIONS22. Function setting (Pr. 520 to Pr. 529)⋅ Pr. 520 to Pr. 529 "trace data CH1 to CH10" (1 to 12, 15 to 20, 23, 24, 32 to 3

Pagina 30 - <Installation>

30Monitor⋅ Pr.533 "Trigger source selection 2" (0 to 23, 25, 26, 29 to 40, 46 to 48, 51, 52, 9999)Pr.532 "Trigger source selection 1&qu

Pagina 31

31MonitorFUNCTIONS2⋅ Pr.535 "Trigger condition"Select whether a trigger will be enabled on the "leading edge" or on the "trai

Pagina 32 - 15) Reference Data

32Monitor(5) Parameter checkParameter check screen1) Present settingParameter value currently stored in the inverter.2) Updated valueNew parameter val

Pagina 33

33DiagnosisFUNCTIONS22.5 Diagnosis2.5.1 VFD StatusChoosing the [Diagnosis] → [VFD Status] command in the menu displays the following screen. VFD Statu

Pagina 35

34DiagnosisNo AlarmDiagnosis (No Alarm): Shows the diagnosis items. When you choose the corresponding item, the panel appears.Enter data in accordance

Pagina 36

35Test RunningFUNCTIONS22.6 Test Running2.6.1 Test RunningChoosing the [Test Running] → [Test Running] command from the menu displays the following sc

Pagina 37 - 1 Trace start

36Test Running<Operation procedure>1) Set the station number of the inverter to be run and the operation mode (PU or LNK (Link) operation).2) Co

Pagina 38 - (5) Parameter check

37Advanced FunctionFUNCTIONS22.7 Advanced Function2.7.1 Machine analyzer (for FR-V500 (L) series only)Machine analyzer reads and analyzes the torque a

Pagina 39 - 2.5 Diagnosis

38Advanced Function(2) Machine analyzer settingMake the following settings when using Machine analyzer.1) Stml condition⋅ "% of rated Torque"

Pagina 40 - Diagnosis

39Advanced FunctionFUNCTIONS2(3) Starting Machine analyzer operation1) Checking the settingsClick the [Start] button to check the settings of "St

Pagina 41 - 2.6 Test Running

40Advanced Function(4) Reading the Machine analyzer operation dataWhen Machine analyzer is started, the following screen appears so that you can check

Pagina 42 - Test Running

41Advanced FunctionFUNCTIONS2(1) Observation of waveformsThe frequency characteristics measured by Machine analyzer are displayed in board charts.For

Pagina 43 - 2.7 Advanced Function

42Saving, Reading and Printing the Files2.8 Saving, Reading and Printing the Files2.8.1 File types2.8.2 Saving method1)*.MEL fileWhen the system setti

Pagina 44 - Advanced Function

43HelpFUNCTIONS22.9 Help2.9.1 Help contentsChoosing the [Help] → [Contents] command from the menu displays the following screen:1) About VFD Setup S/W

Pagina 45

CONTENTS1 OVERVIEW 11.1 Before Using This Software ... 21.1.1 Packing lis

Pagina 47

4512343 ERROR INDICATIONS3.1 Error codes ...46This chapter explains the "error ind

Pagina 48 - 2.8.4 Printing

46Error codes3.1 Error codes3.1.1 Error code listsWhen any error occurs, the corresponding error code is output to the error code display column (indi

Pagina 49 - 2.9 Help

4712344 APPENDICES4.1 Supplementary Software ...48This chapter provides the "appendices" for use o

Pagina 50

48Supplementary Software4.1 Supplementary Software4.1.1 IntroductionThe parameter file edit software (hereafter "PREDIT") is specifically de

Pagina 51 - ERROR INDICATIONS

49Supplementary Software APPENDICES4(2) Parameter file structureThe parameter file consists of a machine information part and a parameter information

Pagina 52 - 3.1 Error codes

50Supplementary Software(1) Input items1) Pr ... Write the parameter number. Set the parameter numbers in the ascending

Pagina 53 - APPENDICES

51Supplementary Software APPENDICES42) Edit (may also be displayed with the right button of the mouse)•CutCuts the currently chosen range and pastes i

Pagina 54 - 4.1 Supplementary Software

52Supplementary Software1) Parameter conditionSet the read disable conditions for other parameters.When adding a condition, press the [Add] button and

Pagina 55 - APPENDICES

53Supplementary Software APPENDICES43) Display• Display columnChoose whether the display column (refer to the input items) is to be displayed or not.•

Pagina 58

REVISIONS*The manual number is given on the bottom left of the back cover.Print Date *Manual Number RevisionNov., 2002 IB(NA)-0600081-A First editionF

Pagina 59

INDUSTRIAL AUTOMATIONMITSUBISHI ELECTRICMITSUBISHI ELECTRICGothaer Strasse 8 Phone: +49 2102 486-0 Fax: +49 2102 486-717 www.mitsubishi-aut

Pagina 60

112341 OVERVIEW1.1 Before Using This Software...21.2 Preparations for Startup...

Pagina 61 - REVISIONS

2Before Using This Software1.1 Before Using This Software• This software can be used effectively as a support tool for operations from startup to main

Pagina 62 - INDUSTRIAL AUTOMATION

3Preparations for StartupOVERVIEW11.2 Preparations for Startup1.2.1 System configurationThe following devices are required to use the VFD Setup Softwa

Commenti su questo manuale

Nessun commento