TRANSISTORIZED INVERTER
INSTRUCTION MANUAL
FR-ABR-(H)0.4K to 22K
HIGH-DUTY BRAKE RESISTOR
H
Vedere la pagina 0
1 2 3 4 5 6 ... 12 13

Sommario

Pagina 1 - FR-ABR-(H)0.4K to 22K

TRANSISTORIZED INVERTERINSTRUCTION MANUALFR-ABR-(H)0.4K to 22KHIGH-DUTY BRAKE RESISTORH

Pagina 2 - WARNING

65. SPECIFICATIONSPermissible duty and torque* The permissible duty represents the braking capability including the motorloss.The actual duty of the r

Pagina 3 - CAUTION

7FR-ABR-11K, 15K, 22K, H11K, H15K, H22K*1 For the 15K, connect two resistors (18Ω) in parallel. *2 For the H15K, connect two resistors (18Ω) in serie

Pagina 4

87. BRAKING CAPABILITIES7.1 Continuous Permissible Power7.2 Short-Duration Permissible Power per BrakingModel ResistanceContinuous Permissible PowerMo

Pagina 5 - APPLICABLE INVERTERS

REVISIONS*The manual number is given on the bottom left of the back cover.Print Date *Manual Number RevisionNov., 1998 IB(NA)-66891-A First editionMar

Pagina 6

A-1Thank you for choosing the Mitsubishi transistorized inverter optionunit.This instruction manual gives handling information and precautions foruse

Pagina 7 - High-duty brake resistor

A-22. Fire Prevention3. Injury Prevention4. Additional InstructionsAlso note the following points to prevent an accidental failure, injury,electric sh

Pagina 8 - 3. INSTRUCTIONS FOR WIRING

A-3INSTALLATION INSTRUCTIONS FOR COMPLIANCE WITH ULInstall the high-duty brake resistor FR-ABR as follows:• The brake resistor may be mounted horizont

Pagina 9 - 4. INSTRUCTIONS FOR USE

11. UNPACKING AND CHECKING THE MODEL AND APPLICABLE INVERTERSTake the brake resistor out of the package and confirm that the product isas you ordered

Pagina 10 - 6. OUTLINE DIMENSIONS

2400V ClassFR-ABR-H0.4KFR-A540-0.4K(-**)FR-E540-0.4K(C)(-**)FR-A044-0.4K(-**)FR-A740-0.4K(-**)FR-ABR-H0.75KFR-A540-0.75K(-**)FR-E540-0.75K(C)(-**)FR-A

Pagina 11 - 1 d1 B2 d2

32. GENERAL INSTRUCTIONS FOR INSTALLATION (For compliance with UL standard, refer to page A-3.)• Never mount the resistor near wood, paper or any othe

Pagina 12 - POWER(W)

43. INSTRUCTIONS FOR WIRINGWhen the regenerative brake transistor is damaged, the wiring sequenceas shown in the following diagrams is recommended to

Pagina 13 - REVISIONS

5• Connect the leads of the high-duty brake resistor to the P and PRterminals of the inverter. When using the FR-ABR-15K, 22K, connecttwo high-duty br